Syringe Pump HF-610B
Features
Syringe pump is with the classic single channel design. It is open system and can accept different syringe brand after calibration. The software compensation error is within±2% after calibration. It is widely used in ICU, NICU, pediatrics, internal medicine, surgery, obstetrics and gynecology, oncology, emergency department and outpatient infusion room. Double CPU and numeric keypad make it more user friendly.
|
Friendly UI Interface |
Like ATM interface |
|
Strong Battery Backup |
3000mAh battery and backup time more than 9hrs |
|
Adjustable Level |
Occlusion, alarm volume, brightness adjustable |
|
Injection Mode |
Constant rate, volume/time, drug mode, micro-mode, programmable mode, etc. |
|
Event Log |
More than 10000 logs |
* The specification is subject to change without prior notice, please refer to real products.
Specifications
|
Item |
Specification |
|
Injection Mode |
Constant rate, time/volume mode, drug weight mode, micro-mode, programmable mode, drug library mode |
|
Syringe Size |
5ml, 10ml, 20ml, 30ml, 50/60ml, auto-recognition |
|
Flow Rate |
5ml: 0.10ml/h-60.00ml/h |
|
Increment |
0.01ml/h |
|
Preset Time |
1s~99hr59min59s |
|
Parameter Changed during Injection |
Support change of VTBI, flow rate during injection |
|
Accuracy |
≤±2%(±1% mechanical accuracy included) |
|
Preset Volume(VTBI) |
0.10-9999.99ml&empty |
|
Accumulated Volume |
0.00-9999.99ml |
|
Purge Rate |
5ml: 30.00-60.00ml/h 10ml: 150.00-300.00ml/h 20ml: 200.00-400.00ml/h 30ml: 300.00-600.00ml/h 50ml: 600.00-1200.00ml/h |
|
Bolus Rate |
5ml: 0.10ml/h-60.00ml/h |
|
KVO |
0.10 -5.00ml/h adjustable |
|
Occlusion Pressure |
8 level adjustable, 20Kpa-150Kpa, dynamically pressure value display. |
|
Item |
Specification |
|
Alarm |
Finished, near finished, near empty, empty, occlusion, syringe disconnected, no operation, parameter error, syringe error, low battery, battery lost, battery ran out, AC power lost, abnormal injection, communication error, finished! KVO. |
|
Syringe Management |
Preset 20 syringe brands, can add or edit the brand, accept different brands after calibration |
|
Display |
3.5’TFT color LCD, 10 level brightness adjustable |
|
Pressure Release Function |
Pressure release function after occlusion |
|
Power Supply |
AC Power: 100V-240V, 50/60Hz, ≦45W |
|
Battery |
Rechargeable Lithium battery, DC11.1V,3000mAh; |
|
Alarm Voice |
Standard Medical Alarm Voice with Mute function, 8 levels adjustable. |
|
Event Log |
10000 event log |
|
Operation Environment |
+5℃- +40℃, Relative humidity:20%-90%; Atmospheric pressure: 70 ‒ 106 Kpa |
|
Classification |
Class II, Type CF; IPX4 |
|
Dimension |
Size: 275mm×145 mm×160mm, Weight: 2.1kg |
|
Other Function |
Double CPU, Password function, 90 ºratable IV pole, 4 soft function key: key lock function, numeric keypad, sleeping function |
|
Application |
Intravenous injection |